Thermocouple extension and compensation cables with braided insulation

MI & Compensation Cables

High-performance cable solutions for accurate temperature signal transmission.

MI Cable

Mineral insulated (MI) cable contains matched thermocouple wires packed in magnesium oxide insulation inside a continuous metal sheath. It can be cut to length and fabricated into thermocouples.

MI cable has several advantages over conventional thermocouples: lengths of up to 100 m are possible, along with long life, quick response and easy fabrication. Keep cut ends sealed, because magnesium oxide absorbs moisture.

  • Available in 1mm, 1.5mm, 3mm, 4.5mm, 6mm, 8mm.
  • Simplex and duplex types, with 316 stainless steel, Inconel 600 or other sheath grades.
Up to 1200°C, depending on sheath and type

Compensation Cables

Extension and compensation cables carry the thermocouple signal from the sensor to the controller. Extension cable uses the same alloys as the thermocouple (grades such as KX or NX). Compensation cable uses lower-cost alloys that match the thermocouple only over a limited temperature range, typically for noble metal types.

Always match the cable to the thermocouple type, and keep the cable ends within its rated temperature range.

  • Used to extend the signal from the thermocouple to the control panel.
  • Available in various insulation types (PVC, PTFE, Fiberglass).
Varies by Insulation Type

Extension vs Compensation Cable

Both extend the thermocouple signal to your controller. The difference is which alloys carry it.

CableConductorsTypically used withNotes
Extension grade (KX, NX, JX, TX)Same alloys as the thermocoupleBase metal types K, N, J and TLowest added error, so the preferred choice where accuracy matters.
Compensation gradeDifferent, lower-cost alloysNoble metal types R, S and BMatches the thermocouple only over a limited range, typically up to about 100–200°C. Saves the cost of platinum wire.

Choosing the Cable Insulation

InsulationApprox. max temperatureBest for
PVCAbout 105°CControl panels, instrument rooms and general wiring
PTFEAbout 260°CMoisture and chemical resistance on mid-temperature runs
FibreglassAbout 480°CHot areas close to the furnace shell
MI cable (metal sheath)Up to about 1200°CInside the hot zone of vacuum furnaces

Ratings are approximate and depend on the cable grade. Confirm the limit for your route with our engineers. In aerospace heat treatment, AMS 2750 accuracy tests cover the whole measurement chain, so the right cable type and grade matter.

Customization & Support

We offer fully customizable cable configurations to meet your exact needs – from conductor type and gauge to insulation, shielding and length. Our team is also available to advise on selection, routing and termination.

Custom Specifications

Tailored cable constructions — conductor gauge, insulation, shielding, and jacketing to match your exact requirements.

Prompt Delivery

Efficient production and logistics to ensure your cables reach you on schedule, in custom lengths as needed.

Technical Support

Expert guidance on cable selection, routing, termination, and signal integrity from our experienced team.

Thermocouple Cable FAQs

What is the difference between extension and compensation cable?

Extension cable uses the same alloys as the thermocouple, so it is accurate over the full range. Compensation cable uses different, lower-cost alloys that match the thermocouple only over a limited temperature range, and is mostly used with noble metal types.

Which cable should I use in a vacuum furnace?

Inside the hot zone, MI cable with a metal sheath is the usual choice because it withstands high temperature and protects the wires. Outside the hot zone, use extension or compensation cable of the same type, with insulation rated for the temperature along the route.

What length of MI cable is possible?

Lengths of up to 100 m are possible, and MI cable can be cut and fabricated to the length you need.

What sizes and sheath materials are available for MI cable?

Diameters of 1, 1.5, 3, 4.5, 6 and 8 mm, in simplex and duplex types, with 316 stainless steel, Inconel 600 or other sheath grades.

Does the cable affect AMS 2750 accuracy?

Yes. AMS 2750 System Accuracy Tests check the complete measurement chain, so use cable of the correct type and grade and keep joints to a minimum.

Need the Right Cable?

Our experts will help you select the perfect MI or Compensation cable for your application.

Contact Us