Calibration Division
Ensure your equipment runs at peak precision with our comprehensive calibration services.
Our Calibration Services

Vacuum or Atmospheric Calibration
- TUS (Temperature Uniformity Survey)
- SAT (System Accuracy Test)
- Resident / Non-Resident / Comparison
- Compliance with AMS2750 / NADCAP / AQI / CQI-9

Thermal or Atmospheric Equipment Calibration
- Furnaces, ovens, heat treaters
- Thermocouple & temperature calibration
- Compliance with AMS2750 / NADCAP / AQI / CQI-9
- Sub-zero chambers up to -100 °C

Controller Calibration
- Temperature & process controllers
- PID tuning
- Multi-channel recorder accuracy checks

Vacuum Sensor Calibration
- Pirani, piezo/Pirani, ionization & capacitance manometer transducers
- Absolute & relative pressure, rough to high vacuum
- Full-scale range accuracy check
- Traceable to national standards

Pressure & Compound Gauge Calibration
- Analog & digital pressure gauges
- Compound gauge accuracy tests
- Ranges: vacuum to 500 bar
Why Choose Us
Our Advantages
- ISO 17025 traceability (sub-contract)
- Fast turnaround times
- Calibration certificates provided
- Experienced, certified technicians
Service Highlights
- Vacuum & atmospheric furnaces
- Thermal equipment & sub-zero chambers
- Controllers
- Vacuum sensors
- Pressure gauges
Add-on Services
- Equipment maintenance
- Emergency calibration
- Validation support
- Documentation audits
Why Calibration Decides the Quality of Every Cycle
Your furnace only does what the instruments say it is doing. If the thermocouples, controller or vacuum sensors are reading a little high or a little low, the cycle follows the error — and the evidence shows up later as hardness spread, case depth that misses the mark, longer cycle times, or parts that behave differently in service.
Calibration is how you close that gap. It establishes that what the controller reports is what the furnace is actually doing, on the equipment you run, at the temperatures and pressures you use — not on a datasheet. For heat treatment plants working to customer specifications or aerospace and automotive standards such as AMS2750, NADCAP and CQI-9, it is also the record that proves the process was under control.
Lakshmi Vacuum’s calibration division works on the furnaces and instruments we build and service every day, covering vacuum and atmospheric furnaces, thermal equipment, sub-zero chambers, controllers, vacuum sensors and pressure gauges — on-site at your plant or in our lab, with ISO 17025 traceability on a sub-contract basis and certificates you can file.
Calibration Scope at a Glance
| Scope | What is checked | Where it is done |
|---|---|---|
| Vacuum or Atmospheric Calibration | TUS (Temperature Uniformity Survey) · SAT (System Accuracy Test) · resident / non-resident / comparison · AMS2750 / NADCAP / AQI / CQI-9 compliance | On-site only |
| Thermal or Atmospheric Equipment Calibration | Furnaces, ovens and heat treaters · thermocouple and temperature calibration · AMS2750 / NADCAP / AQI / CQI-9 compliance · sub-zero chambers up to -100 °C | On-site or in-lab |
| Controller Calibration | Temperature and process controllers · PID tuning · multi-channel recorder accuracy checks | On-site or in-lab |
| Vacuum Sensor Calibration | Pirani, ionization and capacitance manometers · full-scale range accuracy check | In-lab or on-site |
| Pressure & Compound Gauge Calibration | Analog and digital pressure gauges · compound gauge accuracy tests · vacuum to 500 bar | In-lab or on-site |
Standard Colour Codes for Thermocouples, Wire and Connectors
| Colour Coding | Extension Grade | Alloy Combination | Comments for Environment (Bare Wire) | Maximum T/C Grade Temp. Range | Plug & Jack | |
|---|---|---|---|---|---|---|
| (+) Lead | (−) Lead | |||||
| J | +− | Iron(Magnetic) | Constantan(Copper-Nickel) | Reducing, vacuum, inert. Limited use in oxidizing at high temperatures. Not recommended for low temperatures. | 0 to 750 °C | Black |
| K | +− | Nickel-Chromium | Nickel-Aluminium(Magnetic) | Clean oxidizing and inert. Limited use in vacuum or reducing. Wide temperature range, most popular calibration. | 0 to 1250 °C | Yellow |
| T | +− | Copper | Constantan(Copper-Nickel) | Mild oxidizing, reducing, vacuum or inert. Good where moisture is present. Low temperature and cryogenic applications. | -250 to 350 °C | Blue |
| E | +− | Nickel-Chromium | Constantan(Copper-Nickel) | Oxidizing or inert. Limited use in vacuum or reducing. Highest EMF change per degree. | -200 to 900 °C | Purple |
| N | +− | Nicrosil(Nickel-Chromium-Silicon) | Nisil(Nickel-Silicon-Magnesium) | Alternative to Type K, more stable at high temperature. | -270 to 1300 °C | Orange |
| R | +− | PlatinumRhodium-13% | Platinum | Oxidizing or inert. Do not insert in metal tubes. Beware of contamination. High temperature. | 0 to 1600 °C | Green |
| S | +− | PlatinumRhodium-10% | Platinum | Oxidizing or inert. Do not insert in metal tubes. Beware of contamination. High temperature. | 0 to 1450 °C | Green |
| B | +− | PlatinumRhodium-30% | PlatinumRhodium-6% | Oxidizing or inert. Do not insert in metal tubes. Beware of contamination. High temperature. Common use in glass industries. | 0 to 1800 °C | White(Uncompensated) |
| C | +− | TungstenRhenium-5% | TungstenRhenium-26% | Vacuum, inert, hydrogen. Beware of embrittlement. Not practical below 399 °C. Not for oxidizing atmosphere. | 0 to 2300 °C | Red |
Colour conventions differ between standards (ANSI, IEC, BS), so confirm the standard your plant and customer follow. Thermocouples, compensating cables and connectors: thermocal@lakshmivacuum.com.
When You Need a Calibration
New equipment goes in
A hot zone, sensor or controller is replaced
Your schedule comes round
Results start to drift
An audit is coming
The process changes
How a Calibration Visit Works
1. Tell us what needs calibrating
2. We agree scope and schedule
3. Calibration is carried out
4. You receive the certificate
Calibration Division — FAQ
Which equipment can you calibrate?
Vacuum and atmospheric furnaces (TUS and SAT); thermal equipment such as furnaces, ovens and heat treaters, including sub-zero chambers up to -100 °C; temperature and process controllers; vacuum sensors including Pirani, ionization and capacitance manometers; and pressure and compound gauges from vacuum up to 500 bar.
Can the calibration be done at our plant?
Yes. Furnace calibration (TUS and SAT) is carried out on-site at your plant. Thermocouples, controllers, sensors and gauges can be calibrated on-site or in our lab, depending on the equipment, the accuracy required and your production schedule.
What traceability and standards apply?
The service is offered with ISO 17025 traceability on a sub-contract basis, aligned with AMS2750, NADCAP, AQI and CQI-9 requirements — the standards your heat treatment customers and auditors ask about.
Do we receive a calibration certificate?
Yes. Calibration certificates are provided for the work carried out, giving you the record your quality system needs.
How quickly can you attend?
Fast turnaround is part of the service, and emergency calibration is available as an add-on when a furnace cannot wait. Scheduling is confirmed as soon as the enquiry is reviewed.
How do we get started?
Send the equipment list, the standard you work to and your preferred timing through Contact Us or an RFQ. The calibration team comes back with the scope, schedule and pricing.